| Specifications | |||
|---|---|---|---|
| Input Voltage from battery: | 5-16VDC | ||
| Load Current: | 30 ma. during static test, 3.5 Amps max. during dynamic test. | ||
| Static indicator transition voltages: | 6V | 12V | INDICATION: |
| less than 6.05 | less than 12.10 | too low to test | |
| 6.05-6.75 | 12.10-13.50 | normal charged battery | |
| 6.75-7.10 | 13.50-14.20 | normal charging voltage | |
| more than 7.10 | more than 14.20 | overcharging/open battery | |
| ALL TRANSITIONS HAVE 50 MILLIVOLT HYSTERESIS | |||
| Dynamic load time interval: | 1.0 to 3.5 Amps, dependent on A.H. selected. | ||
| Dynamic load time interval: | 120 to 270 seconds, depending on battery voltage and A.H. selection (all intervals +/-%) | ||